The HEARTS@GSI facility / Cave A showcasing a sample setup for electronics irradiation (left) and the current electronics target station (right). In the left picture the beam traverses from the left to right, exiting the vacuum exit window, through the beam monitors until it hits the devices under test. In the right picture the beam points towards the viewer. (Image: GSI)
General facility parameters
Typical value | Extra information | |
---|---|---|
Ion species | U | |
Beam flux | 102 – 105 ions/cm2/s
|
Higher values are also possible. |
Spill timing | 5s length with 2s pause | The spill length is adjustable between 0.2 – 10s in length. |
Beam delivery | Raster scanning | For more information see links below. |
Beam size | adjustable up to 5×5cm2 | The size is freely adjustable, as magnetic raster scanning is used. |
Uniformity | better than ±5% | |
LET range | 17 – 40 MeV·cm2/mg
|
Typical beam properties
Extraction energy [MeV/u] |
Energy at DUT [MeV/u] |
LET in Si [MeV·cm2/mg]
|
Range in Si [mm] |
---|---|---|---|
900 | 882 | 17 | 39 |
600 | 581 | 19 | 22 |
400 | 378 | 22 | 11.9 |
300 | 275 | 25 | 7.4 |
200 | 169 | 32 | 3.6 |
150 | 113 | 40 | 2.0 |
Next expected availability
- June 2025 via RADNEXT Transnational Access
- Note that the related RADNEXT proposals would need to be submitted during the current RADNEXT TA call until 31st January 2025!
- GSI beamtime schedule (Row “SIS” marked as “RADNEXT” in green)